Example of Regulation: Radiant System for Heating and Cooling of 6 Zones with Dehumidifier and Heat Pump
In this example, the REG System manages a radiant heating and cooling system with one dehumidifier and a heat pump, in detail the Reg manages the following components:
- 6 zones (kitchen, living room, bedroom 1 and 2, bathroom with tub and shower);
- a dehumidifier;
- a mixed circuit for the heating and cooling radiant floor system;
- a direct circuit for the dehumidifier in summer and for a vertical designer radiator in winter;
- a buffer tank;
- an external temperature probe
- a heat pump (set point via 0 / 10V, ON / OFF and heat/cool switch via dry contact, alarm signal input).
In addition, the REG-DOT-B display touch screen temperature and humidity sensor is used for the living room, which allows you to manage the system remotely via Wi-Fi.
Click on the following links to view the electrical and hydraulic diagrams!
EXAMPLE_1_HYDRAULIC-SCHEME_EN.pdf
EXAMPLE_1_ELECTRICAL-SCHEME_EN.pdf
Example of Regulation: Home Heating and Cooling Power Plant with Boiler and Heat Pumps
In this example, the REG System manages a home heating and cooling power plant consisting of two heat pumps and a boiler, in detail the Reg manages the following components:
- two heat pumps via Modbus (with dedicated firmware) both for heating and cooling and one for domestic hot water production;
- a boiler via OpenTherm to support heating in winter and to support DHW production
- a buffer tank;
- an external temperature probe;
- a DHW storage tank and its recirculation pump;
- two mixed and one direct circuits.
The GSM module is used to control the system remotely.
Click on the following links to view the electrical and hydraulic diagrams!
EXAMPLE_2_HYDRAULIC-SCHEME_EN.pdf
EXAMPLE_2_ELECTRICAL-SCHEME_EN.pdf